午夜影视

<big id="ssvaa"></big>
    <code id="ssvaa"></code>

    <object id="ssvaa"><nobr id="ssvaa"></nobr></object>

    1. <tr id="ssvaa"></tr>

      <th id="ssvaa"><sup id="ssvaa"></sup></th>

      <th id="ssvaa"><option id="ssvaa"></option></th>
      1. Continuous Emission Monitoring System

        • Price:

          Negotiable

        • minimum:

        • Total supply:

        • Delivery term:

          The date of payment from buyers deliver within days

        • seat:

          Beijing

        • Validity to:

          Long-term effective

        • Last update:

          2020-06-27 07:16

        • Browse the number:

          159

        Send an inquiries

        Company Profile

        Xi'an Dingyan Technology Co., Ltd.

        By certification [File Integrity]

        Contact:dykeji(Mr.)  

        Email:

        Telephone:

        Phone:

        Area:Beijing

        Address:Beijing

        Website:http://www.dycems.com/ http://dykeji.shh-dingchao.com/

        Product details

        Continuous Emission Monitoring System

        Continuous Emission Monitoring System is applied to monitor emission of chimney in industrial pollution sources. The measuring components include SO2, NOx, O2, dust, humidity, temperature, pressure, flow velocity,etc.CEMS have obtained CCAEP certification from China Environmental Protection Ministry and a number of technical patents, which is high stable performance.

        Applications of system
        1.Chimney
        2.After the precipitator

        3. Channel of chimney entrance

        System features
        1. Display the real-time monitoring data, transfer data to the client computer and environmental protection department platform simultaneously. Data can be reported, stored, queried, exported, and printed.
        2. Adopt high temperature resistant sampling probe and efficient sample gas processing system, low component loss rate.
        3. Gas analyzer adopts UV DOAS principle, with fast response speed, strong anti-interference ability, and high measurement accuracy.
        4. The system has rich interfaces and strong expandability.
        5. On-site installation and technical training from technicians. The overall modular design facilitates maintenance. The technical team can provide remote technical support and on-site guidance.

        Spec.

        Product

        CEMS

        Continuous emission monitoring system

        Model

        DY-FG200

        Measuring components

        SO2,NOx,O2,dust,etc

        temperature,pressure,flow velocity

        Measuring range unit

        Unit:ppm,mg/m3

        Measuring range

        SO2,NOx:0~50~100~200~500mg/m3,0~500~1000~2500ppm,

        O2:0~25%.

        Temp.:0~500℃,humidity:0~40%,pressure:-2.5KPa~+2.5KPa,

        Flow:0~40m/s.

        Range can be customized

        Measuring principle

        SO2,NOx:UV DOAS.

        Dust:laser backscattering ,O2: electrochemistry

        Temperature: thermal resistance

        Pressure: metal diaphragm

        Velocity: pitot tube differential pressure

        Humidity: resistance capacity

        Sampling method

        extraction

        Response time

        ≤200S

        Linearity error

        ± 2% F.S.

        Zero drift

        ± 2% F.S./24h

        Span drift

        ± 2% F.S./24h

        Analog output

        4~20mA DC

        Digital output

        RS232/RS485

        Power supply

        AC220V+10%,50Hz

        Atmospheric pressure

        80KPa-106KPa

        Purge gas

        Instrument-grade compressed air

        Environment humidity

        ≤90%RH

        Ambient temperature

        -20℃~+50℃

        Installation

        Ground-mounted

        Size

        600mm*800mm*2200mm

        Explosion-proof

        optional


        http://www.dycems.com/

        午夜影视
        <big id="ssvaa"></big>
        <code id="ssvaa"></code>

        <object id="ssvaa"><nobr id="ssvaa"></nobr></object>

        1. <tr id="ssvaa"></tr>

          <th id="ssvaa"><sup id="ssvaa"></sup></th>

          <th id="ssvaa"><option id="ssvaa"></option></th>